Gas Boiler Not Working or Won’t Turn On? What to Check
There’s never a good time for your boiler to stop working, and it always seems to happen on the coldest morning of the week. Before you panic, it’s worth knowing that a lot of gas boilers that “won’t turn on” have a simple cause: the power, the gas supply, the pressure or the thermostat. You can check all four safely in about ten minutes.
This guide takes you through those checks in the order we’d do them ourselves, explains what’s going on when the boiler has power but won’t fire up, and makes it clear when it’s time to stop and call a Gas Safe engineer. If you have an oil boiler, our oil boiler not firing up guide is the one you need.
Smell gas? Don’t touch any electrical switches. Turn off the gas at the meter if you can, open doors and windows, leave the property and call the National Gas Emergency line on 0800 111 999.
Gas boiler with no power or not firing? Start here
The first question is simple: is there any sign of life on the boiler? Lights, a display or a pressure reading all count. Use this table to jump to the right section.
| What you see | Most likely cause | Where to look |
|---|---|---|
| No lights or display at all | Electrical supply | No power section |
| Display on, but no flame and no heat | Gas, pressure, controls or a lockout | Power but won’t fire section |
| A fault code on the screen | A specific fault the boiler has detected | Fault code section |
| Hot water works, heating doesn’t | Controls, diverter valve or motorised valve | Hot water but no heating section |
| Heating works, no hot water | Usually a hot water-side fault | Our no hot water guide |
Gas boiler has no power (no lights or display)
If your boiler is completely dead, the problem is almost always electrical rather than with the boiler itself. Check these in order:
- The fused spur switch. This is the switch on the wall near the boiler, often with a small red light. Make sure it’s on. It’s easily knocked off during cleaning or decorating.
- Your consumer unit (fuse box). Look for a tripped RCD or circuit breaker and reset it. If it trips again straight away, leave it off and call an electrician or us.
- A power cut. Check whether other lights and sockets are working.
- The fuse in the spur. If the switch is on and there’s power elsewhere, the fuse in the spur may have blown. Replacing it with the correct rating is safe, but if it blows again there’s a fault that needs an engineer.
- The programmer or timer. Some boilers look dead when the clock has been reset after a power cut and is simply outside its on periods.
If you have power at the spur but the boiler still shows nothing, the issue is likely inside the boiler, such as an internal fuse or the main circuit board (PCB). That’s a job for a Gas Safe engineer.
Gas boiler has power but won’t fire up
If the display is on but the boiler won’t light, work through these causes. They’re listed in the order we come across them most often in homes around Hinckley and Leicestershire.
The gas supply is off or the prepayment meter has run out
Check whether your gas hob lights. If it doesn’t, the problem is the supply, not the boiler. On a prepayment meter, top up and follow the instructions on the meter to restore the supply (this often means pressing a button). Then reset the boiler so it tries to light again.
Also check the emergency control valve next to your gas meter. The handle should be in line with the pipe. If it’s across the pipe, the gas is off.
Boiler pressure is too low
Most gas combi boilers won’t fire if the pressure drops below about 0.5 to 1 bar. Look at the gauge. If it’s low, our guide on how to repressurise a boiler walks you through topping it up to 1 to 1.5 bar. If you find you’re doing this often, take a look at why boiler pressure keeps dropping.
The condensate pipe has frozen
This is a big one in winter. If it’s been below freezing overnight and your boiler has locked out (often with a gurgling noise), the plastic pipe that carries water away from the boiler may have frozen. It can usually be thawed safely with warm (not boiling) water. Our frozen condensate pipe guide shows you how.
The thermostat or programmer isn’t asking for heat
The boiler will only fire when something tells it to. Turn the room thermostat up a few degrees above the current temperature and check the programmer is in an “on” period. If you have a wireless thermostat, replace the batteries and check it’s still paired with the boiler. A blank thermostat screen is a very common cause of a “broken” boiler.
The boiler has gone into lockout
If the boiler tries to light and fails, it will lock out to protect itself. You’ll usually see a flashing light or fault code. A single reset is fine (see the reset section below), but if it locks out again, there’s an underlying fault that needs looking at.
An ignition or flame sensor fault
If you can hear the fan start and the boiler clicking but it never lights, or it lights and then cuts out, the ignition electrode or flame sensor may be faulty or dirty. These parts are inside the sealed case, so they need a Gas Safe engineer.
A fan, gas valve or PCB fault
Less often, a component fails: the fan that clears fumes, the gas valve that lets gas into the burner, or the circuit board that controls everything. These faults usually come with a fault code and always need an engineer.
Boiler fires for hot water but not central heating
If your hot taps run hot but the radiators stay cold, the boiler itself is working. The problem is with how it switches between heating and hot water. Common causes are:
- the thermostat or programmer not calling for heating
- a stuck diverter valve inside a combi boiler, which decides whether hot water goes to the taps or the radiators (see our boiler diverter valve faults guide)
- a faulty motorised valve on a system or regular boiler
- a pump that has stuck after a quiet summer
If only one or two radiators are cold, the boiler is probably fine. Our guide to radiators not heating up will help.
How to reset a gas boiler safely
Most modern boilers have a reset button or a reset position on the control dial. The exact method depends on the make, so check your manual, but generally:
- Worcester Bosch: press and hold the reset button for a few seconds.
- Vaillant: press the reset button (often marked with a flame or an R).
- Baxi: press the reset button, sometimes held for a few seconds.
- Ideal: press reset, or on some models turn the control dial to the reset position.
Wait a couple of minutes for the boiler to run through its start-up. Don’t reset it more than twice. If it locks out again, resetting repeatedly won’t fix it and can make some faults worse.
Showing a fault code? Use the brand guide
If your boiler is showing a code, it’s telling you exactly where to look. Our brand guides explain what each code means and what you can safely try:
- Vaillant boiler fault codes
- Worcester Bosch boiler error codes
- Ideal: F1, F2 and L2
- Baxi: E133 and E119
- Glow-worm: F1 and F22
When to stop and call an engineer
You’ve done everything a homeowner safely can once you’ve checked the power, gas supply, pressure, condensate pipe and controls, and tried one or two resets. Please don’t remove the boiler casing. Everything inside is gas-side work, and by law it must be done by a Gas Safe registered engineer.
Call us if:
- the boiler locks out again after a reset
- you hear the fan and clicking but it never lights
- the fuse in the spur keeps blowing
- there’s water leaking from the boiler
- there’s a fault code you can’t clear
If the boiler is getting on in years and this isn’t the first breakdown, our guide on whether to repair or replace your boiler may help you weigh things up.
Gas boiler breakdowns in Hinckley and nearby
Our Gas Safe engineers repair gas boilers across Hinckley, Nuneaton, Leicester, Coventry and Rugby, along with the surrounding villages. We’ll find the fault, explain it in plain English and give you a clear price before we start. We know how unsettling it is to be without heating and hot water, so we’ll aim to get you warm again as soon as we can.
Frequently asked questions
Why is my boiler not turning on when it has power?
The most common reasons are low pressure, no gas supply, a frozen condensate pipe or the thermostat not calling for heat. Check those first, then try one reset. If it still won’t fire, call an engineer.
My boiler isn’t working but there’s no fault code. What does that mean?
With no code, the boiler often isn’t being asked to fire. Check the thermostat batteries, the programmer times and the pressure. A boiler that’s completely blank with no code usually has an electrical supply issue.
Can a faulty thermostat stop my boiler from firing?
Yes. If the thermostat’s batteries are flat or it has lost its connection, the boiler never gets the signal to turn on. It’s one of the most common call-outs we attend that turns out not to be a boiler fault at all.
Is it worth repairing an old boiler that keeps breaking down?
It depends on the age, the fault and how often it happens. A one-off repair on a well-kept boiler is usually worth it. Repeated breakdowns on a boiler over 10 to 15 years old often make replacement better value.